Quinn Engineering Sample Project Plan Viewer: Plans may take a minute to load, please be patient.
A sampling of our project display plans and site photos: Click on Site Address for individual site pages containing larger thumbnails with links to full sized pictures or click the images below for medium sized images that open in a new window.
307 Grafton Street, Shrewsbury: Site Plan for Office/Commercial Business; some of the tasks for this project: Hydrology and stormwater management drainage and groundwater recharge system design for the proposed building and parking lot which discharges fully treated stormwater to the existing municipal drainage system, layout for future expansion of the parking lot, work within a riparian zone (riverfront area), and septic system design. The site required utility connection to municipal water. (780kb) MAP
290 West Main Street, Northborough: Site Plan for Office/Commercial Businesses; some of the tasks for this project: Hydrology and stormwater management drainage and groundwater recharge system design for the proposed building and parking lot which discharges fully treated stormwater to the existing municipal drainage system. The site included work in a groundwater protection overlay district and required utility connection to the municipal sewer, water, and gas mains in West Main Street. (1.2Mb)MAP
291 Grafton Street, Shrewsbury: Site Plan for a Bank: Hydrology and stormwater management drainage and groundwater recharge system design for the proposed building and parking lot which discharges fully treated stormwater to the existing municipal drainage system. The site included work within a riparian zone (riverfront area), parking lot configuration, and connection to sewer and water mains in Grafton Street. (668kb)MAP
St. Nicholas Church, Shrewsbury: Site Plan for a Church; some of the tasks for this project: Hydrology and stormwater management drainage and groundwater recharge system design for the proposed building and parking lot which discharges fully treated stormwater to the surrounding wetlands, wetland replication, and layout for future expansion of building, parking lot, and drainage system. The site required utility connection to municipal sewer, water, and gas mains in Gold Street. (664kb)MAP
Turtle Creek Circle, Shrewsbury: Site Plan for a Residential Subdivision; some of the tasks for this project: Hydrology and stormwater management drainage and groundwater recharge system design for the proposed roadway and buildings which discharges fully treated stormwater to the surrounding wetlands and stream, roadway layout and profile, work within a riparian zone (riverfront area), and connection to municipal sewer, water, and gas mains located in Main Circle. (1.7Mb) MAP
Glenwood Estates - Phase II, Grafton: Site Plan for a Residential Subdivision. Some of the tasks for this project: Hydrology and stormwater management drainage and groundwater recharge system design for the proposed roadway which discharges fully treated stormwater to the surrounding wetlands, roadway layout and profile, work within a riparian zone (riverfront area), and wetland crossing and replication. (1.6Mb)MAP
Highland Village, Paxton: Site Plan for Senior Housing Project. Some of the tasks for this project: Hydrology and stormwater management drainage and groundwater recharge system design for the proposed roadway and buildings which discharges fully treated stormwater to the surrounding wetlands, roadway layout and profile, design of a sewer that is pumped to a common leach field, and connecting the municipal water main in Forestdale Road through to Highland Street. (4Mb)(512kb)MAP
677 Pleasant Street, Paxton: Septic System Repair Plan for a Restaurant. Some of the tasks for this project: Design of an inground and sloped Presby Environmental septic system, including bottom drain sumps under a parking lot, and utilizing a vent manifold. The design included separation of kitchen flows to a grease trap and reductions of setbacks due to site constraints. (336kb)MAP
Note: The plans are for display purposes only and are not for permitting or construction.